M3-LS micro stage developer’s kits provide easy evaluation and prototyping. All kits include the linear positioning stage, embedded controller, USB adapter and Pathway PC software. Contact us to create 2-axis and 3-axis systems, or to inquire about volume pricing or customization of M3-LS Linear Smart Stage systems.

Features

  • Three M3-LS-3.4-15 Smart Stage with integrated controller, 15 mm travel
  • M3-USB USB adapter, Breakout board & Power Supply
  • New Scale Pathway software
  • Cables and mounting hardware kit

    Unmatched precision, stability and ease of use

    The piezo-driven positioning stage has 0.5 µm resolution for precise, repeatable positioning of optics, probes, sensors and more. Absolute encoding removes the need to home the stage on power-up, eliminating errors and disruptions in processes and experiments.

    The M3-LS micro stage has high stiffness and lateral stability, no backlash, and less than 10 µm runout over its full travel range.

    Direct input via USB, I2C or SPI

    The M3-LS Smart Stage – a linear stage with embedded controller – accepts direct input of simple high-level motion commands. It is the only linear micro stage that can be driven directly from a system processor via standard I2C or SPI interface.

    Alternatively, a USB adapter enables connection to a PC, with New Scale Pathway™ software providing an easy-to-use graphical user interface. You can control multiple positioning stages from a single screen for interactive operation. Employ the intuitive script generator to create command sequences for automated operations.

    Low voltage, low power use for hand-held systems

    The integrated piezoelectric motor holds position without using power. The internal electronics can be switched to sleep mode for extreme low-power applications. Unlike other piezo stages, there is no internal high voltage.

    Specifications

    Model M3-LS-3.4-15 M3-LS-U2-8 M3-LS-1.8-6
    Description Longer travel, higher load capacity Linear Smart Stage: micro positioning stage with built-in controller High-speed Linear Smart Stage for high-volume applications: micro positioning stage with built-in controller Ultra-compact Linear Smart Stage: micro positioning stage with built-in controller
    Data sheet (PDF) M3-LS-3.4-15 data sheet with drawings (PDF) M3-LS-U2-8 data sheet with drawing (PDF) M3-LS-1.8-6 data sheet with drawings (PDF)
    Travel Range (Stroke) 15 mm 8mm 6 mm
    Dimensions 32 x 32 x 11 mm including controller 32 x 32 x 10 mm including controller 29 x 20 x 9.5 mm including controller
    Mass of Smart Stage (including controller)
    30 grams including controller
    36 grams (+ cable + connector)
    15 grams including controller (note 1)
    8 grams including controller
    Max moving mass (vertical)
    (note 2)
    100 grams 5 grams payload mass recommended (note 3) 10 grams recommended
    Max moving mass (sideways and horizontal)
    (note 2)
    200 grams 20 grams payload mass recommended (note 3) 20 grams (offset < 10 mm) recommended
    Force (operating) 1 N >= 0.3 N holding force
    >= 0.1 N bidirectional
    0.2 N
    Speed (at operating force) > 4 mm/s 35 mm/s 5 mm/s
    Duty cycle 50% max recommended 50% max recommended (note 8)
    Closed-loop performance
    Resolution 0.5 μm with absolute encoding 0.5 μm with absolute encoding 0.5 μm with absolute encoding
    Bi-directional repeatability < 5 μm ± 5 μm < 5 μm
    Accuracy < 20 μm ± 10 μm < 20 μm
    Input Power (note 4) 6 VDC +/- 5%
    5 W typical at 4 mm/s, 1 N load, closed-loop
    < 0.2 W quiescent
    5 VDC (4.75 V to 5.5 V)
    ~3.2 W peak at max speed and force
    ~0.35 W quiescent
    3.1-5.0 VDC, 3.3 VDC nominal
    Typical power is 1 W @ 3.3V DC input when operating closed loop at 5mm/s driving a vertical load of 10 grams
    Peak operating power is 3.5 W @ 3.3V DC input
    Typical quiescent power is 0.2 W
    Mechanical Stage
    Static parallelism < 30 μm < 30 μm < 30 μm
    Run-out < 10 μm < 10 μm < 10 μm
    Pitch and yaw < 1 mrad < 1 mrad < 1 mrad
    Absolute max load 10 N see data sheet 10 N
    Linear slide features Crossed roller bearings with high stiffness Linear ball bearing races Uniform and very low friction even under high direct loads and side loads. Six ball bearings in a kinematic “v” guide-way eliminate cage creep and friction spikes.
    Environment
    Relative humidity < 70% < 70% < 70%
    Operating temperature (note 5)
    +5 °C to +40 °C -30 °C to +70 °C -30 to +70 °C
    Storage temp. -40 °C to +85 °C -40 °C to +80 °C -40 to +80 °C
    Lifetime  50 km travel (Note 6) >10 million random moves while not exceeding 1.2 km total travel (note 7)
    Compliance  CE / RoHS RoHS / CE pending CE / RoHS
    Controller embedded embedded embedded
    Control interface Directly via I2C or SPI serial interface
    Indirectly via USB adapter to PC
    Directly via I2C or SPI serial interface
    Indirectly via USB adapter to PC
    Directly via I2C or SPI serial interface
    Indirectly via USB adapter to PC

    Note 1: For the M3-LS-U2-8 smart stage, moving mass of the stage carriage without payload is ~6 grams
    Note 2: Higher moving mass is possible but affects performance and lifetime
    Note 3: For the M3-LS-U2-8 smart stage, torque due to gravity of the payload calculated from center point (see the coordinates in the data sheet PDF) on the carriage is recommended to be within 1.5 Nmm. Also recommend center of gravity of the payload above the carriage surface to be <=15 mm.
    Note 4: Power depends on input voltage, speed and load
    Note 5: Speed and force reduced at lower temperatures within the range
    Note 6: Tested horizontally, with 20 grams load offset 8.75 mm at reverse position
    Note 7: Corresponds to 10 million moves with an average random move of 120 µm. Lifetime depends on the application and use case.  Please consult the factory to discuss your specific system design.
    Note 8: A <50% duty cycle is recommended for operating at room temperature (25 °C or below) and mounting the stage on a surface with a good thermal conduction path to dissipate heat. Please consult NST for when operating at higher ambient temperatures.

     

    srtj